Add the relay node #19

Merged
rob merged 1 commit from feat/relay-node into main 2026-11-16 21:37:58 +00:00
Collaborator

A fourth board: the lighting node's core and button inputs with six relays in place of the light outputs. Five are 10 A and one is 25 A, for 230 V AC or 12 V and 24 V DC loads in any mix. 134.5 × 70 mm, two layers, with a case.

The relays have reinforced insulation between coil and contacts. RelayNode.kicad_dru holds 6.4 mm between each relay's load copper and everything else. I planted a track 1.8 mm from a load pour to confirm DRC objects to it.

ERC reports 0 violations. DRC reports 0 errors and 0 unconnected, with the same warning types as the lighting node.

Open points before ordering boards:

  • Relay 6 is a TE T9GV1L14-5. TE's drawing does not label which holes the single-throw version uses. The footprint assumes the standard T90 pattern and has not been checked against a part.
  • TE gives no DC rating table for relay 6. The README's 20 A at 12 V is read from the breaking curve. For a 24 V van it names a Hongfa part that fits the same holes but must not switch mains.
  • The case builds as valid solids and renders correctly. It has not been printed.
  • Merging cuts a release with this board's order files and case.

The core's placement and tracks are the lighting node's, apart from the supply terminal, which moved 7.5 mm left.

A fourth board: the lighting node's core and button inputs with six relays in place of the light outputs. Five are 10 A and one is 25 A, for 230 V AC or 12 V and 24 V DC loads in any mix. 134.5 × 70 mm, two layers, with a case. The relays have reinforced insulation between coil and contacts. `RelayNode.kicad_dru` holds 6.4 mm between each relay's load copper and everything else. I planted a track 1.8 mm from a load pour to confirm DRC objects to it. ERC reports 0 violations. DRC reports 0 errors and 0 unconnected, with the same warning types as the lighting node. Open points before ordering boards: - Relay 6 is a TE T9GV1L14-5. TE's drawing does not label which holes the single-throw version uses. The footprint assumes the standard T90 pattern and has not been checked against a part. - TE gives no DC rating table for relay 6. The README's 20 A at 12 V is read from the breaking curve. For a 24 V van it names a Hongfa part that fits the same holes but must not switch mains. - The case builds as valid solids and renders correctly. It has not been printed. - Merging cuts a release with this board's order files and case. The core's placement and tracks are the lighting node's, apart from the supply terminal, which moved 7.5 mm left.
Six relays in place of the lighting node's outputs: five 10 A and one
25 A, for mains or 12 V and 24 V loads in any mix. The relays have
reinforced insulation, and a design rule holds 6.4 mm between each
relay's load copper and everything else.
rob merged commit 21a76d698a into main 2026-11-16 21:37:58 +00:00
rob deleted branch feat/relay-node 2026-11-16 21:37:58 +00:00
Sign in to join this conversation.
No reviewers
No labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
The due date is invalid or out of range. Please use the format "yyyy-mm-dd".

No due date set.

Dependencies

No dependencies set