A fourth board: the lighting node's core and button inputs with six relays in place of the light outputs. Five are 10 A and one is 25 A, for 230 V AC or 12 V and 24 V DC loads in any mix. 134.5 × 70 mm, two layers, with a case.
The relays have reinforced insulation between coil and contacts.
RelayNode.kicad_druholds 6.4 mm between each relay's load copper and everything else. I planted a track 1.8 mm from a load pour to confirm DRC objects to it.ERC reports 0 violations. DRC reports 0 errors and 0 unconnected, with the same warning types as the lighting node.
Open points before ordering boards:
The core's placement and tracks are the lighting node's, apart from the supply terminal, which moved 7.5 mm left.